If the wrong o-ring size was used, that could cause the problem. Automatic reset is immediate after error is corrected. I have a S-210 Hayward pool pump and it started spitting sand so I bought a Folding Umbrella Lateral Holder AssY when I dumped the sand out I think 2 of them were broken for a couple of months it seems sand has been dumping in the pool thats why I bought the lateral. If the filter multiport was recently re plumbed, be sure that the pipe from the pump goes into the valve port labeled PUMP, and the pipe to the pool is connected to the valve port labeled RETURN. Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions. Relays are usually small cubes, about 1 square, sometimes black, sometimes clear, mounted on a circuit board. I even tried another new housing gasket and it still leaks. Im assuming that the motor makes no noise at all? Replace with the exact same capacitor (look at the MFD rating printed on the capacitor). i cleaned the filter put the cover back on turned the pump but it doesnt seem to be priming . Pump should be OK, I would think. Hi Paul, Ants can be a problem, when they get around motors or circuit boards, but it sounds like a pump motor problem, and could simply be a weak capacitor, in the rear of the motor (black cylinder). The centrifugal switch may be loose, or the stationary switch may be bent and not releasing. I just purchased a brand new Hayward Super Pump 1.5HP for my pool that is being renovated. Many valve actuators have a small toggle switch that can be used to activate the valve motor, to turn the valve, it may have gotten switched accidentally and is closing off Spa Jets (when it should be closing off pool returns). And 93, thats just the temp of the water, the flames are much hotter of course, thats what is melting the plastic. If it does make a humming or buzzing sound briefly and trips the breaker, check that the shaft rotates the impeller freely, and if so, replacing the capacitor is usually the fix. Hayward Pump Makes Noise. Hi Rachel, when there is no sound at all i would check the circuit breaker to be sure it is on. Just purchased a Hayward SP32002VSP. Drying off the terminal board may help, by removing the rear cover. My 2 year old 1.5 HP above ground Hayward pool pump worked fine last year. My pump was tripping the breaker after about three minutes (consistently when I reset the breaker and turned on the pump, same thing). Breville Tamper Coffee Kit 54mm, I was wondering, I have four returns coming into one pipe to the pump basket. {
Could be too big for the pipe size, although normally I would think that a 1hp should be fine, but do a wheel RPM test on the cleaner (28-32 RPM of the wheel is ideal), and bleed off excess water pressure at the wall fitting. If theres no power at the switch/timer, go back further to the breaker. Superpump lid gaskets are a square cut gasket that can come out of the groove easily, be sure it is seated properly, and lube it with Teflon pool lube regularly. Any suggestions?? Troubleshooting a Hayward Aqua Rite can be quick and simple. that is quite unusual, the 3/4 hp Super II is designed to pull much less, probably around 12 amps. Something about level of placement of pump in relation to the water surface. Inspect the gasket as well, for nicks, dry-rot or other damage that may affect the seal. You will need a new plug and a new outlet and maybe a new pump too (? Usually get 3-4x that long. IF its a broken off grease cap, tap in a sharp screwdriver into where it threads in, to get some bite, and then slowly and firmly back out the broken off threaded connector, turning CCW, then replace with a new Grease Cap, or a 1/8 threaded plug. Is there a thicker housing oring that could be installed to fix the leak? Or a stuck skimmer weir. Some controllers have a Service Mode button you push, to be able to turn off equipment at the equipment pad, as opposed to an in-house remote panel. Thanks. I took off the cover to see the circuit board and all looks ok but then it started coming on and off randomly while I was standing there. It runs fine but no strong circulation. All Lighting Equipment Hayward Sense and Dispense AQL-CHEM Troubleshooting Manual (36 pages) Lighting Equipment Hayward SwimPure Plus Operation And Installation Manual (20 pages) Lighting Equipment Hayward Sheer 500 Owner's Manual Water feature with led lighting (16 pages) Lighting Equipment Hayward OmniHub Installation Manual The second thing that can cause such a problem is if the pump is starved for water, cavitating, because it is too large (hp) for the piping system, or because incoming valves are closed, or pipes are plugged, or clogged. Not the 12VAC that it says should be there. I was hoping that you can give me some advice. It worked great last year, and when i went to program it this year, it didnt work unless I switch it on and off manually. "dateModified": "2/24/2015",
Pump does not overheat or shut off or anything and continues to circulate the water normally, just making a lot of noise, so I have not been running it. As I started to prep for this season, I did notice that the positive and negative electrical terminals on the 3 prong cord were corroded and loose. Specialties: Cycling, Kickboxing, This advanced blue media lasts for the life of the cartridge to inhibit the growth of bacteria on the pleated fabric that can foul and weaken a cartridge. I have replaced the Aqua Rite printed circuit board and the T-Cell-9. Just got it a couple of weeks ago. Any suggestions? Only get big time cavitation and the basket empties about half. Then you can pump out the water with a submersible pump, or depending on the surface material and design of your water feature, it may be better for the surfaces not to drain it, but to treat it with chemicals and put a heavy cover over it, where possible. Weve tried everything. It worked fine just prior to a filter cleaning. But not a dirty filter? Automatic reset is immediate once the gas valve relay check results are acceptable. I hope new filters fix the problem!!! Hi! Hi Anessa, Hayward VS pumps are known to have Drive Errors, whereas Pentair, I dont hear so many problems about the Intelliflo. I can turn the temperature up but not down. If all is good, there is a possibility that the breaker or GFCI outlet is bad. "author": {
https://www.afternic.com/forsale/haywarddocs.info?utm_source=TDFS&utm_medium=sn_affiliate_click&utm_campaign=TDFS_GoDaddy_DLS&traffic_type=TDFS&traffic_id=GoDaddy_DLS the sound may possibly be a problem with the internal bypass, located in the front header. This advanced blue media lasts for the life of the cartridge to inhibit the growth of bacteria on the pleated fabric that can foul and weaken a cartridge. Motor again started humming and had to repeat the above steps each time I moved to backwash. Check for power with a multimeter, at the timeclock and at the pump motor terminal board. So, I dont think you can use this motor, (sorry), unless you are able to add another 110V wire, and run both connected wires from a Double pole breaker. Hope that helps! We are headquartered in Valley Stream, New York, just outside of New Theory and practice | Find, read and cite all the research you need on ResearchGate We would like to show you a description here but the site wont allow us. Yesterday the breaker tripped. Is this rectifier bad? that sounds like loose wires, or broken wires. Products, View If the shaft does spin fine, and is not locked up, you can try a new capacitor, or check your current cap, with an ohmmeter. "author": {
Third possibility is the pipe size is too small, and your 90 gpm pump may be starved for water. Fixing this issue can be tricky, so we suggest you get the help of a certified professional. Check all wires, to be sure that the metal ends of wires are not touching any metal ends of the motor housing, or contacting other wire metal ends. Its that time of season to close the pool, I am probably going to close the pool and worry about the tripping breaker next year. Is the motor still good. How to Read and Adjust the Hayward Aqua Rite SCG Operational Values. Hi, might have been a small clog in the pipe. I needed to rotate the housing pump but for some reason the screws dont seem to b lined up. Flipping the switch makes nothing happen. If they are within range, replace drive. Likely not a problem with the pump itself. We replaced the handle assembly and valve per Hayward tech support that hasnt fixed the problem. Ive read online it is most liked a valve that is faulty in some way. Do you have to find the pump up with water before turning it on? What is happening is that the pump pulls so hard that either an air leak around the pump develops, or the vacuum hose or pool to pump hose begins to crimp and collapse. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Davy, Gail, good luck! The pump shuts off because it trips the circuit breaker in the house. better tool to use? Is there a break in period for the unit or do I need to call the technician? SOme pumps have an open bracket where you can see the shaft, but not Hayward. Went out today to find the lower plastic shroud melting again? Hello Capt., there is not a thicker o-ring available, but you could possibly seal it up with Blue RTV Silicone, i.e. I changed my sand a few weeks and tested it and it worked fine. Does anyone know how to reset an sf error code after a new thermistor has been installed? If recalibrating your salt level did not resolve your problem, then your cell or your PCBoard is bad and needs replacing. High will run fine but next day I have to do the same, start with low and switch to high. Hard pumping can also cause a pump to overheat, but not usually. If you program the incorrect cell size, the salt level, amperage, and voltage will not be correct and the system will turn off. Do I need to prime it? This code will display if 120V polarity is reversed, low voltage is detected, or if the ground path is not sufficient. type of, Kreepy type swimming pool cleaners - known as Suction Side Cleaners, are the simplest type of pool cleaner, and hence one of, Polaris Pool Cleaner Tune-Up Instructions I took a drive around the Beltway last weekend and opened cousin Joe's pool in Chevy Chase,, Troubleshooting Hayward Gas Heater Error Codes, Swimming Pool Covers: The Good, The Bad, The Ugly, Pool Cleaner Tune-Up Kreepy Type Pool Cleaner repair, https://www.google.com/search?client=firefox-b-1-d&q=hayward+h-150+manual, https://www.afternic.com/forsale/haywarddocs.info?utm_source=TDFS&utm_medium=sn_affiliate_click&utm_campaign=TDFS_GoDaddy_DLS&traffic_type=TDFS&traffic_id=GoDaddy_DLS. I bought a new pump thinking was something wrong with pump on off switch. it will not pull up off the pump basket. Holy smokes! Loose pump lid, filter lid, air bleeder, probably around the filter, allowing the filter to drain down, and fill with air. One of those areas can be sealed up to stop the leak. Maybe the breaker is loose on the bar, or perhaps insects shorting it. Turn on the Drain King to pressurize all the way up to the pump, or to the filter valve, and whatever you see leaking water thats your air leak. Known for being reliable & durable, Hayward pool pumps have always been our leading line of pumps. I have a Hayward Power-Flo LX pump that went out and I bought the identical one thinking it would be an easy replacement. 1. drain plug HELP!!! If the blower prover switch opens unexpectedly during operation the control will shut down and attempt to re-light. I tried to prime the pump but it still doesnt kick over to cycle anything. Zero on the gauge indicates no water flow, so if not an air leak it could be a clogged line, pump basket or impeller. Or you can try a filter cleaner first, to remove oils and scale that may be clogging the filter. You may have a partially clogged burner orifice, which is the brass spray tip on the end of the burner tube, where the gas shoots out of the manifold. Washed out the 4 Large cartridge filters before startup. If the shaft spins freely, no rust problem. I have replaced my existing super pump with new one.